Customization: | Available |
---|---|
Classification: | Biological Diagnostics |
Type: | Monitor |
Still deciding? Get samples of US$ 400/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Functions
Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1)ECG Heart rate(HR)
ECG waveform
Arrhythmia and ST-segment analysis
2)RESP Respiration rate(RR)
Respiration waveform
3)SpO2 Oxygen saturation(SpO2)
Plethysmogram(PLETH) waveform
Pulse rate(PR)
Bar graph
4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMP T1, T2, TD
6)IBP(optional) CH1:SYS, DIA,MAP
CH2:SYS, DIA, MAP
IBP waveform
7)CO2(optional) EtCO2
InsCO2:Inspired Minimum CO2
AwRR: Air Way Respiration
It has abundant functions, such as audible and visual alarms, trend data storage and output, NIBP measurement, alarm event marking, drug concentration calculation, etc.
Performance
ECG
Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: 5-lead, dual-channel
3-lead, single-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR: Measurement and alarm range: 15~350 bpm
Accuracy: ±1 % or ±1 bpm, whichever is greater
Alarm accuracy: ± 2 bpm
Resolution: 1 bpm
ST-segment monitoring:
Measurement and alarm range: -2.0 mV ~ +2.0 mV
Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater
Other range: unspecified
Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Pacemaker: yes
RESP
Method: R-F(RA-LL) Impedance
Respiration rate:
Measurement and alarm range: 0~150 rpm
Resolution: 1 rpm
Measurement accuracy: ±2 rpm
Alarm accuracy: ±3 rpm
Apnea alarm: 10~40s
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
NIBP
Method: Oscillometry
Mode: Manual/AUTO/STAT
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
Measurement period in STAT mode: 5 minutes
Measurement and alarm range: 10 ~ 270 mmHg
Resolution: 1 mmHg
Cuff pressure accuracy: ±3 mmHg
Measurement accuracy:
Max mean deviation: ±5 mmHg
Max standard deviation: 8 mmHg
Over-pressure protection:
Adult mode: 297±3 mmHg
Pediatric mode: 240±3 mmHg
Neonatal mode: 147±3 mmHg
SpO2
Measurement and alarm range: 0 ~ 100%
Resolution: 1%
Measurement accuracy: 70%~100%: ±2%;
0%~69%: unspecified
PR
Measurement and alarm range: 30 ~ 250 bpm
Measurement accuracy: ±2 bpm or ±2%, whichever is greater
TEMP Channel: dual-channel
Measurement and alarm range: 0 ~ 50ºC
Resolution: 0.1 ºC Accuracy: ±0.1 ºC
EtCO2
Method: Sidestream or Mainstream
Measuring Range: 0~150mmHg
Resolution: 0~69 mmHg, 0.1 mmHg 70~150 mmHg, 0.25 mmHg
Accuracy: 0~40 mm Hg ±2 mm Hg 41~70 mm Hg ±5% 71~100 mm Hg ±8% 101~150 mm Hg ±10% AwRR
Range: 2~150 rpm AwRR Accuracy: ±1BPM Apnea Alarm: Yes
IBP
Channel: dual-channel
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and Alarm Range: -10~300 mmHg Resolution 1 mmHg Accuracy: ±2% or 1mmHg, whichever is greater
Power supply: 100-240V~, 50/60Hz Safety classification: Class I, type CF defibrillation-proof applied part
Product Name
|
Portable Veterinary Monitor
|
SKU
|
VE12
|
Size
|
38*35*30cm
|
Material
|
Plastic
|
Sample Time
|
3-10 Days
|
MOQ
|
1 pcs
|
Accessories
|
Standard accessories: SpO2 probe*2 Blood pressure cuff*2 Blood pressure extension tube*1 ECG lead wire*1 Body temperature sensor*1 Power cord*1 Integrated ground wire*1 Manual*1 Lithium battery*1 |
Delivery
|
Shipping By Sea. Air and Express
|
Delivery time
|
15-45 Days
|
OEM/ODM
|
Available
|
Port of shipment:
|
Shanghai/Ningbo
|
Other
|
Accept Your Special Demands. Let You Save Time and Worries.
|