Full Digital LED Machine Pocket Portable Laptop Ultrasound

Product Details
Customization: Available
Customized: Customized
Certification: CE, FDA, EEC, ISO13485
Still deciding? Get samples of US$ 1000/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Full Digital LED Machine Pocket Portable Laptop Ultrasound
  • Full Digital LED Machine Pocket Portable Laptop Ultrasound
  • Full Digital LED Machine Pocket Portable Laptop Ultrasound
  • Full Digital LED Machine Pocket Portable Laptop Ultrasound
  • Full Digital LED Machine Pocket Portable Laptop Ultrasound
  • Full Digital LED Machine Pocket Portable Laptop Ultrasound
Find Similar Products

Basic Info.

Model NO.
WMVU-P60
Scale
Small
Battery
Contains
Fundamental Frequency
Eight Levels Frequency Conversion
Display Mode
B/C, B/C/M, B/Power, B/C/Pw
Mirror Image Reversal
up/Down, Left/Right
Monitor
15 Inches
Transport Package
Paper Box
Trademark
Weemed
Origin
China
Production Capacity
50000PCS/Year

Product Description

Products Pictures
Full Digital LED Machine Pocket Portable Laptop UltrasoundFull Digital LED Machine Pocket Portable Laptop UltrasoundFull Digital LED Machine Pocket Portable Laptop Ultrasound

Product Description

2. Application
2.1. Applicable for animals' examination and diagnosis on digestive system, reproductive system,
urinary system for animal hospitals and scientific institutions.


3. System Technical Specifications and Summary
3.1. Full digital color doppler ultrasound diagnostic system
3.2. Digital Beam Enhancer
3.3. Multiple Beam Synthesis
3.4. Full-Digital 2D Gray Scale Imaging
3.5. Tissue Harmonic Imaging (THI)
3.6. B/C Real-time Two Synchronous Imaging
3.7. M Mode Imaging
3.8. Anatomic M Mode Imaging (Sampling line≥3)
3.9. Color Doppler Imaging (CFM, PDI, DPDI)
3.10. Spectral Doppler Imaging (PW, HPRF PW, CW)
3.11. Tissue Doppler Imaging (TVI, M-mode, Spectral Imaging, etc.)
3.12. Four-dimensional Supersonic Image Formation
3.13.★Contrast Tuned Imaging
3.14.★PView Wide Field Imaging
3.15. Space compound imaging (application to Abdominal, GYN, vessel, superficial small organs, can
be dual image contrast display at same time)
3.16. Frequency & Focus Compound
3.17. Extended field-of-view (EFOV)
3.18. Real-time dual image contrast display
3.19. B/C/D Real-time three synchronous imaging
3.20. Speckle Reduce Imaging (SRI)
3.21. Elastography


4.★Operation Interface: support 10 different languages

5. System Specification
5.1. Monitor: 15 inch high resolution medical LCD monitor
5.2.★Probe connectors: ≥2 active, support all probes
5.3. 2D Imaging Mode
1)Full Digital Beamformers
2)Digital full dynamic focusing, digital variable aperture and dynamic trace change, A/D≥15 bit
3)Receiving mode: transmitting and receiving channel ≥1024, multi-signal parallel processing
4)Line density: ≥512, visible and adjustable
5)Under B mode, focus number≥10 level, focus position continuously adjustable
6)TGC: 8 segment adjustable
7)Gain: B / M / D separately adjustable, ≥100dB
8)★Dynamic range ≥180dB
9)★Max scanning depth ≥360mm
10)Grey scale: 0-67, visible and adjustable
11)Sound power: 1%-100%
12)Linear array probe two-dimensional independent deflection
13)ZoomPIP (1.5 / 2.0 / 2.5 / 3.0 / 3.5 / 4.0 / 4.5 / 5.0 / 10 times)

5.4. Color Doppler Imaging Mode
1)Imaging: including velocity, velocity variance, energy, direction energy display, etc
2)Display mode: B/C, B/C/M, B/POWER, B/C/PW
3)Line density ≥3 level
4)Color hiding technology: without back to B mode can hide C mode, only color speed ruler display
5)Blood flow graph, color flow profile to measure intravascular velocity


5.5. Spectral Doppler Imaging
1)Display: full screen, duplex / triplex (PW only)
2)Gain ≥100dB
3)Velocity ≥4 level adjustable
4)Max scanning speed: PWD: Positive or negative blood flow velocity≥7.6m/s;
CWD: blood flow velocity ≥20.0m/s, min ≤5 mm/s (Nonnoise signal);
5)Zero shift adjustable ≥8 level
6)Display mode: B, PW, B/PW, B/C/PW, B/CW, B/C/CW, etc
7)Automatic Spectrum Measurement, Manual Measurement
8)Display control: reverse, zero shift, B refresh, D extension, B/D extension, etc
9)Smart Doppler technology: freely switch between real-time B+CFM mode and real-time PW mode


5.6. ★PView wide field imaging
1)High-resolution display, length can up to 50cm
2)Imaging support forward erasure, no need to re-imaging
3)With two dimensional wide view imaging mode and color wide view imaging mode


5.7. Probe: wideband with frequency conversion, independent frequency conversion under B and CFM
1)Fundamental Frequency Conversion≥3 level;
2)1. Convex probe
Fundamental frequency: nine levels frequency conversion
2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz,
Harmonic Frequency: 4.0MHz/4.6MHz/5.0MHz, three levels frequency conversion
2. Linear probe
Fundamental frequency: nine levels frequency conversion
4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz
Harmonic Frequency: 8.0MHz/9.2MHz/10.0MHz, three levels frequency conversion
3. Phased array probe
Fundamental frequency: nine levels frequency conversion
1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz
Harmonic Frequency: 3.4MHz/3.8MHz/4.2MHz,three levels frequency conversion
4. High frequency phased array probe
Fundamental frequency: eight levels frequency conversion:
3.0MHz/3.5MHz/4MHz/5MHz/5.4MHz/6MHz/7MHz/8MHz,
Harmonic Frequency: 6MHz/7MHz/8MHz, three levels frequency conversion
5. Micro-convex probe
Fundamental frequency: eight levels frequency conversion
3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz
Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, three levels frequency conversion


5.8. Technical requirements for electronic convex probe:
Frequency: 2.0-5.4 MHz, lateral resolution: ≤2 (depth≤80), ≤3mm (80axial resolution: ≤1 (depth≤80), ≤1mm (80dead zone: ≤3mm; Geometric position accuracy: broadwise: ≤5%; lengthwise:≤5%
detecting depth>=240mm


5.9. Technical requirements for electronic linear probe:
Frequency: 4.0-13.3MHz, lateral resolution: ≤1 (depth ≤40),
axial resolution: ≤0.5 (depth ≤50),
dead zone: ≤3mm; Geometric position accuracy: broadwise: ≤4%; lengthwise: ≤2%
detecting depth >=100mm


6. Measurement / Analysis and Reports
6.1. General measurement: distance, area, ellipse, cross line, angle, distance ratio, volume, volume
(ellipse), area ratio, diameter, joint angle.
6.2. Specialized measurement:
1) Cardiac: Automatic spectrum envelope, LV, Main Pulmonary artery diameter, RVEDd, RVEDs,
LVM, LAV, HR, MVF, AO, AR, LVOT, TVF, Pulmonic valve, Pulmonary vein, RV, Doppler fetal
heart sound, LVET, LVM, LVMI, AV
2) Vascular: carotid intima (IMT), length stenosis ratio, area stenosis ratio, IMT (back wall), IMT
(front wall)
3)★OB: Canine: GSD, CRL, HD, BD; Feline: BD, HD; Swine: HLA, SLA;
Bovine: CRL, BTD, BUD; Ovine: SCRL, BPD; Equine: GSD(H), ESD (V)
4) Urinary measurement: Prostate, residual urine, left kidney, right kidney, left adrenal gland,right adrenal gland, left testis, right testis, left seminal vesicle, right seminal vesicle.
5)Abdomen measurement: liver, common hepatic duct, diameter of portal vein, gallbladder, common
bile duct, pancreas, spleen, abdomen aortic diameter, kidney.
6)Organella.


7. Peripherals Section
7.1. Configured ultrasonic graphic work station, the work station software equipped with registration
certificate, supports black and white digits, simulation B/W, digit color, simulation color, text and
video printer, and foot switch
7.2. Support Internet connection
7.3. Support DICOM 3.0, report of DICOM Obstetrics and Gynecology / Heart / Blood Vessel
7.4. Video/Audio Input Output
7.5. Main unit comes with USB port
7.6. Support ultrasonic system directly sent clinical images and reports through Internet.


8. Cine Loop and Original Data Processing
8.1. Cine Loop ≥ 3061 frames, support manual and auto operation
8.2. Original Data Processing, can conduct offline parameters analysis on static files and replay
dynamic images. Such as Gain, Pseudo Color, Grey Scale Curve, ect.
8.3. Digitalization Hard Drive Capacity ≥ 256G, support permanent store static, dynamic images, can be
consulted, transferred, deleted freely
8.4. Multiple Image Export Modes: Dynamic Image and Static Image exported in PC format, Images
can be seen on regular PC devices, no need of specific software.
can process diagnosis, export and backup image data at the same time without affecting the
inspection operation
8.5. Professional probe holder ≥2 (coupling holder not included)

Full Digital LED Machine Pocket Portable Laptop Ultrasound

Application
Full Digital LED Machine Pocket Portable Laptop UltrasoundFull Digital LED Machine Pocket Portable Laptop UltrasoundFull Digital LED Machine Pocket Portable Laptop Ultrasound
Full Digital LED Machine Pocket Portable Laptop Ultrasound
Certificates
Full Digital LED Machine Pocket Portable Laptop Ultrasound


Factory
Full Digital LED Machine Pocket Portable Laptop UltrasoundFull Digital LED Machine Pocket Portable Laptop UltrasoundFull Digital LED Machine Pocket Portable Laptop Ultrasound
Exhibition
Full Digital LED Machine Pocket Portable Laptop UltrasoundFull Digital LED Machine Pocket Portable Laptop Ultrasound

Customer Feedback
Full Digital LED Machine Pocket Portable Laptop UltrasoundFull Digital LED Machine Pocket Portable Laptop Ultrasound

Related Products
Full Digital LED Machine Pocket Portable Laptop UltrasoundFull Digital LED Machine Pocket Portable Laptop UltrasoundFull Digital LED Machine Pocket Portable Laptop Ultrasound

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier